Honeywell SYA14 Series Manual page 647

Safety light curtains
Table of Contents

Advertisement

Installation Instructions for the
FF-SRD5985
Safety Door Monitor Module
IMPROPER INSTALLATION
Consult with US and/or European safety agencies and
their requirements when designing a machine control,
interface and all control elements that affect safety.
Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in
death or serious injury.
PRODUCT DESCRIPTION
Protective gates are designed to limit or block access to the
moving parts of dangerous machinery. These gates can be
equipped with locking or interlocking devices, usually safety
limit switches or any other safety sensors.
The FF-SRD5985 Safety Door Monitor module monitors
the status of these safety sensor positions. When the
protective gate is open, the initiation of dangerous motion is
prevented. When the door is closed again, the next
machine cycle can start, but only after initiating a manual
restart sequence.
This device has two safety relays with positive-guided
contacts to ensure redundancy.
This safety control module provides an emergency stop
signal to the machine control circuitry. FF-SRD5985 helps
to create a control reliable safety solution by providing
redundancy and self-checking circuitry. Other features
include high current capability, an increased number of
contacts
(using
an
extension
SRE3081), external relay monitoring and input closure
timing.
APPROVALS
CE
The product, packaging and
documentation of FF-SR Series
products carry the CE mark; the CE
declaration of conformity is available
upon request.
cULus
This product is pending approval by
(pending)
Underwriters Laboratories Inc.
according to Canadian and U.S.
safety requirements.
BG
German Berufsgenossenschaft
E+MIII
PK 107013-01-EN FR26 GLO 398 Printed in Germany
control
module
FF-
PK 107013-01
(pending)
DIRECTIVES COMPLIANCE
Machine Directive 89/392 EEC
Low Voltage Directive 73/23 EEC
Electromagnetic Compatibility Directive 89/336
REGULATIONS COMPLIANCE
Regulation
Title
OSHA 29 CFR
General Requirements for
1910.212
(guarding of) All Machines
OSHA 29 CFR
(Guarding of) Mechanical Power
1910.217
Presses
STANDARDS COMPLIANCE
Standard
Title
ANSI B11.1
Mechanical Power Presses
ANSI B11.2
Hydraulic Power Presses
ANSI B11.19
Safeguarding when Referenced by
the Other B11 Machine Tool Safety
Standards
ANSI/RIA
Safety Requirements for Industrial
R15.06
Robots and Robot Systems
UL508
Underwriters Laboratories
EN 292
Safety of Machinery - Basic
Concepts, General Principles for
Design
EN 60204
Safety of Machinery - Electrical
Equipment of Machines
EN 954
Safety of Machinery - Safety related
parts of control system
0217355