Honeywell SYA14 Series Manual page 297

Safety light curtains
Table of Contents

Advertisement

FF-SM Series Installation Manual
Fiber Optic Cable Connections
The fiber optic cable exits the safety mat at the mid-point of the mat length. All safety mats
are equipped with a peripheral cable duct to allow fiber optic cable exit alternatives during
installation. The protective sleeve of the cable duct is designed to bend as required to allow
the cable to fit completely into the duct. This feature allows easy installation of two safety
mats in a side-by-side configuration. See figure 2-14.
The rigid PVC sheath and protective sleeve allow bending of the fiber optic cable at exits and
corners of the safety mat while ensuring protection.
Figure 2-14 Cable Duct
The fiber optic cable pairs must be protected against damage. The openings, cable ducts,
and chutes must be dimensioned so that the fiber optic cable and connectors can be installed
into them with ease. The cable duct and chutes must comply with the minimum
recommended bending radius of 30 mm (1.18 in).
FIBER OPTIC CABLE DAMAGE
• Do not trap the fiber optic cable with the trim edges.
• Do not lay the safety mat down on the fiber optic cable.
Failure to comply with these instructions will result in product damage.
Fiber optic cables and power cables from other sensors may be installed in the cable duct
together without disturbing the operation of the safety mat.
For application help: see Warranty Information
Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France 23