Installation
Calculate the safety distance using the following formula:
FLOOR MOUNTING SAFETY DISTANCE FORMULA
D
> V(t
+ t
) + C
S
1
2
Standards
D
= minimum safety distance
S
V = approach speed
t
= response time of the safety mat
1
t
= stopping time of the machine
2
(sec)
C = additional distance
Figure 2-1 Floor Mounting
Figure 2-2 Step Mounting
12 Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France
US (in)
ANSI B11.19-1990
E44.33.1
application dependent
63 in/sec
0.025 sec
application dependent
66 to 84 in
Floor Mounting Safety Distance Formula (European/US)
D
mm > 1600(t
+t
)+1200 (European)
S
1
2
D
in > 63(t
+t
)+C, where C is between 66 to 84 inches
S
1
2
(US)
Note: Ensure hardguarding protection is installed on the
rear face and on both sides.
Step Mounting Safety Distance Formula (European)
D
mm> 1600(t
+ t
) + (1200 - 0,4H) or
S
1
2
D
in> 63(t
+ t
) + (47.3 - 0.4H), where:
S
1
2
D
= minimum safety distance (mm or in)
S
t
= response time of the safety mat (sec)
1
t
= stopping time of the machine (sec)
2
H = height of the platform (mm or in)
Note: Ensure hardguarding protection is installed on the
rear face and on both sides.
FF-SM Series Installation Manual
EUROPE (mm or in)
prEN 999
application dependent
1600 mm/sec or 63
in/sec
0.025 sec
application dependent
1200 mm or 47.3 in
D
S
D
S
H
For application help: see Warranty Information