Honeywell SYA14 Series Manual page 714

Safety light curtains
Table of Contents

Advertisement

Installation Instructions for the
FF-SRS5939
Interface Control Module
for Safety Light Curtains
IMPROPER INSTALLATION
• Consult with US and/or European safety agencies
and their requirements when designing a machine
control, interface and all control elements that
affect safety.
• The FF-SRS5939 interface control module is
designed
to
be
electrosensitive protective equipment using fail-
safe solid state outputs. These equipment perform
cross-fault detection between their outputs. The
FF-SRS5939 module does not perform the cross-
fault detection between its inputs. To ensure the
highest safety category, do NOT use the FF-
SRS5939
with
any
electrosensitive protective equipment equiped with
relay outputs, use the FF-SRS5935 or FF-
SRS5925 dual channel emergency stop module,
and for the electromechanical
use the FF-SRD5985 door monitoring module.
These three modules perform the cross-fault
detection between their inputs.
• Strictly adhere to all installation instructions.
Failure to comply with these instructions could
result in death or serious injury.
PRODUCT DESCRIPTION
The FF-SRS5939 interface control module is
designed to be used in emergency stop circuits
when danger to personnel or machinery is present.
This device has two internal safety relays with
positive-guided contacts to ensure redundancy.
This safety module provides an emergency stop
signal to the machine control circuitry. FF-SRS5939
helps to create a control reliable safety solution by
providing redundancy and self-checking circuitry.
Other features include high current capability, an
automatic start and manual start mode and external
relays monitoring.
APPROVALS
CE
The product, packaging and
documentation of FF-SR Series
products is pending CE mark
following an examination by BG
(
German Berufsgenossenschaft
E+MIII)
cULus
This product is pending approval
(pending)
by Underwriters Laboratories Inc.
according to Canadian and U.S.
safety requirements.
(pending)
used
with
Honeywell
other
equipment.
For
safety switches,
PK 107033-EN
DIRECTIVES COMPLIANCE
Machine Directive 98/37/EEC
Low Voltage Directive 73/23 EEC
Electromagnetic Compatibility Directive 89/336
REGULATIONS COMPLIANCE
Regulation
Title
OSHA 29 CFR
General Requirements for
1910.212
(guarding of) All Machines
OSHA 29 CFR
(Guarding of) Mechanical
1910.217
Power Presses
STANDARDS COMPLIANCE
Standard
Title
EN 292
Safety of Machinery - Basic
Concepts, General Principles
for Design
EN 60204 - 1
Safety of Machinery -
Electrical Equipment of
Machines
EN 954 - 1
Safety of Machinery - Safety
related parts of control
system
EN 61496 - 1
Safety of Machinery-
ElectroSensitive Protective
Equipment.
UL508
Underwriters Laboratories
ANSI B11.1
Mechanical Power Presses
ANSI B11.2
Hydraulic Power Presses
ANSI B11.19
Safeguarding when
Referenced by the Other
B11 Machine Tool Safety
Standards
ANSI/RIA R15.06
Safety Requirements for
Industrial Robots and Robot
Systems
107033-12 EN FR26 GLO 0499 Printed in Germany