Honeywell SYA14 Series Manual page 684

Safety light curtains
Table of Contents

Advertisement

MODE SETTING
ELECTRICAL SHOCK
Remove power from FF-SR Series control modules
and machine during installation and before setup.
Failure to comply with these instructions could
result in death or serious injury.
To set the desired mode of operation, remove the
front panel (see figure 7). Refer to the back of the
front panel for switch setting options (see figure 8).
Set switches as required, then replace front panel.
S1 AND S2 SWITCHES
Refer to the important warnings on page 6.
This module contains two internal switches (S1 and
S2) that are used to set various modes of operation.
This feature ensures application flexibility.
Switches S1 and S2 are used to select automatic
start and manual start with or without cross fault
detection.
Switch S1 is used to select an operating mode for
cross fault detection between the two inputs.
Cross fault monitoring must be used when two
independent safety inputs are provided to this
module to increase the overall safety level of the
solution (see typical application examples).
Switch S2 is used to select automatic start
("Autostart") or manual start ("Handstart").
Terminals S33 and S34 must be connected for
automatic start to function.
In either mode, if the safety device is actuated
(emergency stop condition occurs), the normally
open contact will open immediately and the normally
closed contact will close. This emergency stop
condition is relayed via the safety contacts of the
module to the machine control circuitry to arrest
dangerous motion and/or remove power.
107017-11 EN FR26 GLO 0999 Printed in Germany
FIG 7. FRONT PANEL REMOVAL
To gain access to the two internal switches, it is
not necessary to remove the terminal blocks.
FIG 8. FRONT PANEL SWITCH SETTING
DIAGRAM
cross fault detection
Factory Setting
4