Overview

This chapter contains operational test procedures, troubleshooting, cleaning, maintenance,
and repair instructions.
IMPROPER MAINTENANCE
Strictly adhere to all maintenance and troubleshooting instructions.
Failure to comply with these instructions could result in death or serious injury.

Operational Test

To ensure operational readiness, perform the operational test at least once a day and every
time the light curtain is repaired or powered up. The operational test consists of passing a test
rod (included with unit) through the sensing field to ensure the light curtain will detect it (see
figure 4-1). The included test rod will have a diameter equal to the resolution of the light
curtain. The resolutions of the FF-SB Series light curtains are as follows:
Light Curtain
FB-SB12
FB-SB14
FB-SB30
Figure 4-1 Operational Test with the Test Rod
56 Honeywell • MICRO SWITCH Sensing and Control
0DLQWHQDQFH DQG
7URXEOHVKRRWLQJ
Resolution
22 mm (0.87 inch)
35 mm (1.38 inch)
30 mm (1.18 inches)
FF-SB Series Installation Manual
For application help: call 1-800-537-6945