FF-SM Series Installation Manual
Figure 2-3 Combined Protective Devices
IMPROPER INSTALLATION OF COMBINED MAT AND MULTI-BEAM TRIP DEVICES
• Ensure the operator cannot stand between the machine and the sensing zone without
activating the safety mat.
• Ensure the operator cannot cross the safety mat without activating the multi-beam trip
devices.
Failure to comply with these instructions could result in death or serious injury.
If zone guarding protection is required, and the machine stopping time is too long in duration
to allow the use of a safety mat alone, use a mat with a multi-beam trip device.
For application help: see Warranty Information
: multi-beam trip device for access control.
Combined Protective Devices Safety Distance Formula
(European)
D
mm> 1600(t
+ t
) + 850 or
S
1
2
D
in> 63(t
+ t
) + 33.5, where:
S
1
2
D
= minimum safety distance (mm or in)
S
t
= response time of the multi-beam trip device (sec)
1
t
= stopping time of the machine (sec)
2
Note: Ensure hardguarding protection is installed on the
rear face and on both sides.
Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France 13
D
S
Installation