40FY Series
MOUNTING DIMENSIONS (for reference only)
Sensor Connector Termination (mm/in)
Magnetic Actuator (mm/in)
2 Honeywell • MICRO SWITCH Sensing and Control
Step 2 - Wire the 40FY sensor as follows:
• If wiring a 2-wire AC type sensor, refer to Wiring
Diagrams (2-wire AC).
SENSOR DAMAGE
• Ensure the AC sensor is wired with a load to
prevent damage to the sensor.
• Ensure a 630 mA fuse (Littelfuse part # 217.630)
is installed in series with the output to prevent
damage to the sensor.
Failure to comply with these instructions could
result in product damage.
• Wire the AC sensor with a load.
• Install a 630 mA fuse (Littelfuse part # 217.630)
in series with the output of the AC sensor.
• If wiring a 3-wire DC type sensor, refer to Wiring
Diagrams (3-wire DC) for sinking or sourcing
configuration.
WIRING DIAGRAMS
3-wire DC NPN (Sinking)
1 BRN
4 BLK
HALL
3 BLU
3-wire DC PNP (Sourcing)
1 BRN
HALL
4 BLK
OUT
3 BLU
3-wire DC Pinout
NO CONNECTION
2-wire AC
L1 BRN
L2 BLU
2-wire AC Pinout
NO CONNECTION
Pollution degree 2. Utilization category: AC12
For application help: call 1-800-537-6945
PK 80370
1557-
+
OUT
LOAD
10 - 30 VDC
-
+
10 - 30 VDC
LOAD
-
L1
FUSE
93 - 132 VAC
LOAD
L2