Honeywell SYA14 Series Manual page 599

Safety light curtains
Table of Contents

Advertisement

Features
Type
Switching capacity
Voltage drop
Protections
Features
Type
Consumption
Low level
High level
Protections
Figure 4.13 : Use of the SSD output for the machine shutdown
+24Vdc
2.5A
K3
SSD
K3 *
32
31
30
SSD
SSD
+24V
Monitoring
OUTPUT
0V
FF-SRM
0V
(*) protect the SSD relay coil with a varistor
107004-15 EN FR26 ROW 0899 Printed in France
SSD output
static DC (NO contact)
0.5 A / 24Vdc
< 1.5 Vdc
galvanic insulation : 500 Vdc, short-
circuits, overloads
SSD MONITOR input
voltage free and without reference
potential
10 mA/24 Vdc
2 mA max.
5 mA min.
galvanic insulation : 500 Vdc
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series