Fuse Replacement
The fuse is located near the relays above the electrical noise filter on the receiver unit (see
figure 4-9). The fuse is in the same location on the emitter power board.
1. Remove the power supply module as directed in the previous section.
Figure 4-9 Fuse
2. Replace the fuse with a 0.5 amp, (120/240 VAC versions) or a 1 amp slow blow fuse (low
voltage version).
3. Replace the power supply module.
4. Perform the operational test to ensure proper functional readiness.