SPECIFICATIONS
Input
Nominal voltage
Nominal consumption
Nominal frequency
Nominal voltage at S13/S23
Nominal input current between S13/S14
Time required for simultaneous contact
S13/S14 and S23/S24
Output
Contact complement
Switching Capability
Current Range (min. to max.)
Voltage Range (min. to max.)
Typical Electrical Life Expectancy
Typical Power Factor (cos ϕ)
General
Temperature range
Housing material
Vibration resistance
Conductor connection
Conductor attachment
NOTE
1:
Install
arc
suppression
device
across
load
to
avoid
module
contact
arcing
and
ensure
specified
relay life expectancy.
NOTE
2:
Total
operations = operations at
power factor 1 multiplied
by the limitation factor. If
the power factor is 0.5 at
230 VAC, 3A (1,000,000
operations), the limitation
factor is 0.70. 1,000,000
x 0.70 = 700,000 total
operations.
CAUTION
CONTACT DAMAGE
To ensure the 1 mA capability during the lifetime of the contact, NEVER exceed 300 mA and 60 V.
Failure to comply with these instructions will result in product damage.
2
120 VAC (-15%, +10%), 230 VAC (-20%, +10%), 24 VDC (-10%, +10%)
35 mA (control line length must not exceed 30 m (98 ft) and must be routed
and S23/S24
closure
Contact type
Response time
3A
5A
10A
0.3
0.5
0.7
1.0
Fuse rating
Mechanical life
Sealing
2
1 x 4 mm
M 3,5 screw terminals; wire contacts are enclosed to prevent electrical shock
Mounting
Weight
FIG 1. CONTACT LIFE FOR 100%
RESISTIVE LOAD (typical) (note 1)
power factor = 1 (cos ϕ)
120, 230 VAC: 4 VA; 24 VDC: 2.5 W
50 to 60 Hz
24 VDC / 0 VDC (provided by control module)
separately from power cables)
2 NO contacts
Safety relay, positive-guided
Activation/deactivation by inputs S13/S14 and S23/S24: 30 ms
Power factor = 1 with resistive load
1 mA to 10A (see caution)
0.1 to 250 VAC/DC
Power factor = 1 at 230 VAC/DC (note 1)
1,000,000 operations
500,000 operations
220,000 operations
Limitation Factor (note 2)
6 A gL (max.)
Ten million switching operations
-15°C to + 55°C (5°F to 131°F) at 90% humidity (max.)
Housing IP 40; Terminals IP 20
Thermoplastic
Amplitude 0.35 mm; Frequency 10 to 55 Hz
solid (max.) [12 AWG] or 2 x 1.5 mm
Quick install rail mounting EN 50022-35
410 g (0.90 lb.)
107011-10 EN FR26 GLO 0499 Printed in Germany
0.5 s
0.45
0.70
0.85
1.00
2
(max.) [16 AWG] stranded wire with sleeve
FIG 2. LIMITATION FACTOR FOR
INDUCTIVE
LOADS (note 2)
power factor < 1 (cos ϕ)