Honeywell SYA14 Series Manual page 252

Safety light curtains
Table of Contents

Advertisement

Indication
The green LED is not illuminated,
the "Alarm" or "Safety" LEDs are
permanently illuminated and the
diagnostic LED is not illuminated.
Head is rotating.
or
or
LED indicators
Green
Red
Yellow
Yellow
« safety»
«alarm» «diagnostic»
Indication
The green LED is not illuminated,
the "Alarm" and "Safety" LEDs
are permanently illuminated. The
diagnostic LED is flickering. Head
is rotating.
LED indicators
Green
Red
Yellow
Yellow
« safety»
«alarm»
«diagnostic»
107006-11 EN FR26 GLO 0300 Printed in Germany
Possible Cause
Optical head may be heavily
contaminated
(fingerprints
dust).
User
zones
have
not
programmed
and
the
scanner is still operating with the
default
" maximum
zones "
settings from the factory.
An
object
is
permanently
detected.
The
installation
environment may have changed
(the detected object could be the
floor).
Possible Cause
Power on self-check sequence,
not completed.
Optical head may be heavily
contaminated
(fingerprints
dust).
External test target error (test
beam has been broken, sensor
has moved, target has moved).
The diagnostic LED will flicker
with 3 extinction sequence.
Unsuccessful programming (if the
last attempt to program the
sensor failed or if it was not
confirmed
by
the
user,
FFSE.EXE will lock itself with
maximum
zones
(alarm
safety). The diagnostic LED will
flicker with 7 extinction sequence
Sensor fault.
If
the
RS232
cable
is
connected
to
the
sensor,
electrical noise interference may
be present.
Corrective Action
Remove power from the sensor and clean
or
the optical head (see section 6.4 "Advice on
maintenance").
been
Use the FFSE.EXE program to set safety
laser
and alarm zones into the laser scanner
Ensure no object is detected by the FF-SE.
Connect the computer. Select the function
"Monitor" in the main menu. Modify the
environment
to
its
characteristics or modify the safety and
alarm zones.
Corrective Action
Ensure the Power ON Self-Check sequence
is completed. This is an internal sequence of
tests which takes 10 seconds
Remove power from the sensor and clean
or
the optical head (see section 6.4 "Advice on
maintenance").
Reset the sensor by turning power off and
on again. If fault continues, reprogram the
external test target with a personal computer
and the FFSE.EXE software
Use
a
personal
FFSE.EXE software program to the redefine
safety and alarm zones.
the
and
Reset the sensor by turning power off and
then on again.
If the diagnostic LED is still flickering,
connect the computer. If communication with
the PC is still possible, select the function
"Monitor" in the main menu. If there is an
error, an error number will appear in the
"Status" window. If the fault cannot be
rectified, return the sensor to Honeywell (see
section 8.1.2 Sales and service).
still
Remove the RS232 cable from the sensor.
original
installation
computer
and
the
44