1.4 Control Reliability
"Control Reliability" means that, "the device, system or interface shall be designed,
constructed and installed such that a single component failure within the device, interface
or system shall not prevent normal stopping action from taking place but shall prevent a
successive machine cycle." (ANSI B11.19-1990, 5.5)
OSHA 29 CFR 1910.217 states that, "the control system shall be constructed so that a
failure within the system does not prevent the normal stopping action from being applied to
the press when required, but does prevent initiation of a successive stroke until the failure
is corrected. The failure shall be detectable by a simple test, or indicated by the control
system."
Honeywell has developed a self-checking technique that combines reliability with safety.
The FF-SRM Series muting module functions with dual channel redundancy and positive
self-check monitoring. This means that a faulty component in our product will make the
muting module fail in a safe mode.
This design meets the highest safety requirements (category 4) described in the EN 954-1
norm. The French Institut National de la Recherche et de la Sécurité has delivered an EC
type examination certificate for an equipment made of a type 4 electrosensitive protective
equipment and the FF-SRM muting module. The whole set complies with the requirements
of the IEC/EN 61496-1 and IEC / pr EN 61496-2 norms.
Category 4 devices are designed and manufactured in such a way that a single breakdown
or an accumulation of failures does not lead to the loss of the safety function when a
dangerous situation arises. The safety function is maintained on a permanent basis.
1.5 Approvals
Approvals
CE
Compliance with the EN954 - parts 1
Standard for category 4 safety related
parts of control systems
cCSAus
10
Description
Only the packaging and the documentation
of FF-SRM Series products carry the CE
mark; the CE declaration of conformity is
at the back of this manual
Canadian Standards Association
107004-15 EN FR26 ROW 0899 Printed in France