Vertical Mounting
IMPROPER INSTALLATION OF FF-SB SERIES LIGHT CURTAIN
• Mount FF-SB Series light curtains so that any entry into protected area must interrupt
sensing field or other safeguarding devices.
• Install mechanical guards or additional FF-SB light curtains to prevent operating personnel
from reaching around, under, or over sensing field.
Failure to comply with these instructions could result in death or serious injury.
Vertical mounting may require the installation of mechanical guards or additional light curtains
to prevent operating personnel from reaching around, under, or over the sensing field (see
figure 2-6).
Figure 2-6 Vertical Mounting
For point-of-operation guarding, the light curtain(s) and any mechanical guards must be
installed to detect or prevent operating personnel from standing between the light curtain and
the danger zone (see figures 2-7 and 2-8).