Installation

Emission Frequency Selection

IMPROPER PERIMETER DEVICE OPERATION
The emitter and receiver must be set to the same light emission frequency for proper
operation.
Failure to comply with these instructions could result in death or serious injury.
The FF-SPS4 Series safety perimeter guarding system has internal switches that are used to
select the emission frequency (F1 or F2) of the infrared modulated light. To avoid crosstalk or
mutual interference when two perimeter guarding systems are close to each other, these
switches need to be set to different frequencies.
Remember, each emitter must be set to the same frequency as its corresponding receiver. If
a receiver receives a signal from two emitters of the same emission frequency, the receiver
remains in an alarm condition permanently. To return to a normal condition, the emission
frequency of the second emitter must be changed; then receiver power must be turned off and
on.
All emitter and receiver devices are factory set to the emission frequency F1 or 50 kHz (see
figures 2-8 and 2-9).
Figure 2-8 Receiver Frequency Selection
Receiver
The position of both switches must be
changed, otherwise the equipment
will remain in an alarm condition.
20 Honeywell • MICRO SWITCH Sensing and Control
Switch positions
Switch
location
Indicators status :
Frequency F1 (50 kHz)
Light On
FF-SPS4 Series Installation Manual
Switch positions
Indicators status :
Frequency F2 (40 kHz)
Light Off
For application help: call 1-800-537-6945