Inspection and Maintenance
Perimeter Guarding Device Replacement (Terminal Strip Version Only)
POWER APPLIED TO MACHINE CONTROL SYSTEM
Turn off and disconnect power from FF-SPS4 Series perimeter guarding device and machine.
Failure to comply with these instructions could result in death or serious injury.
1. Turn off and disconnect power to the perimeter guarding system and the machine.
2. Remove the perimeter guarding device (emitter or receiver) from its mounting and place it
on a clean, level working surface.
3. Using a #15 TORX driver, loosen the four captive screws on the side of the unit (see figure
4-2). The captive screws cannot be removed from the cover.
4. Remove the cover.
5. Remove the rubber part of the plastic conduit and make a hole to allow the cable to go
through.
6. Put the cable through the plastic conduit and connect the wires back in the correct
locations.
7. Push gently but firmly on the orange tab on the green connector with a small, flat-head
screwdriver.
8. Slide the wire inside the hole and release the orange tab.
9. Pull gently on the wire to ensure a secure connection.
10. Repeat for all wires.
11. Install the ground located on the bottom, right side of the device.
12. Check, and change, if necessary, the frequency selection before closing the cover (see
Frequency Selection procedure).
13. Replace the cover and secure the cover with four screws using a #15 TORX driver.
14. Perform the operational test to ensure proper functional readiness.
46 Honeywell • MICRO SWITCH Sensing and Control
FF-SPS4 Series Installation Manual
For application help: call 1-800-537-6945