FF-SB Installation Manual

Light Curtain Order Guide

Catalog listings for the FF-SB Series light curtains include: one emitter, one receiver, two
mating plugs for the metal quick-disconnect connectors, two arc suppressors, one test rod,
and this installation manual.
The three safety relays R1, R2, and R3, the cycle start push-button, and the test contacts
(shown in the wiring diagram in Chapter 3) must be supplied by the customer. Mounting
brackets, accessories, and mirrors must be ordered separately.
Each set of mounting brackets includes the following hardware: bolts, nuts, washers, and
vibration dampeners. For a typical light curtain installation, two sets of mounting brackets are
necessary; one for the emitter and one for the receiver. An emitter or receiver may require
different types of mounting brackets in certain applications.
If the light curtains are mounted directly to a machine, order the mounting accessories set (FF-
SBZS8000). Mirrors are supplied with mounting brackets and accessories.
FF-SB12 Series
Resolution: 22 mm (0.86 in)
FF- SB12E/R o o o - S2
Example: FF-SB12E/R04K-S2
1
The unit automatically switches to the applied AC voltage level.
For application help: call 1-800-537-6945
1
K = 120/240 VAC
(unit size > 200 mm)
E = 120 VAC only (unit size = 200 mm)
Nominal protected height
02 = 200 mm (7.87 in)
04 = 400 mm (15.75 in)
06 = 600 mm (23.62 in)