Quick-Connect Connector Wiring - Honeywell SYA14 Series Manual

Safety light curtains
Table of Contents

Advertisement

FF-SPS4 Series Installation Manual

Quick-connect Connector Wiring

The following tools are necessary:
• A set of wire strippers.
• A medium-sized flat-head screwdriver.
• A crimping tool (reference FF-SBZCRIMP)
• A removal tool for crimped contacts (reference FF-SBZREMOV).
To ensure the specified immunity to electrical noise, the ground terminal of FF-SPS4 must be
connected to the main ground of the machine.
Install a wired pin into the quick-connect connector as follows:
Ensure cable wire is installed through reducer and user plug before wiring pins to connector.
1. Strip about 8 mm (0.3 inch) of insulation from the wire end.
2. Using a FF-SBZCRIMP crimping tool, crimp the pin onto the wire.
3. Push the pin into the correct slot in the connector and through all reducers. Tabs on the
sides of the pin will expand into slots and hold the pin in place when properly seated.
Remove a pin from the connector as follows:
1. Remove the gray plastic receptacle from the plug.
2. Remove the ground screw.
3. Using a screwdriver, pry up the edges of the plastic retainer piece on each side of the
receptacle.
4. Slide the plastic retainer up and remove it.
5. Slide the metal part on each side down, and remove it.
6. Using a screw driver in the side slots, push the top part off.
7. Using a FF-SBZREMOV removal tool, slide the tool over the pin and push it until the
spring releases the pin; remove pin.
For application help: call 1-800-537-6945
(see figures 3-2, 3-4, 3-5 and 3-6)