Display Oam Critical-Event - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

Field
Errored-frame-seconds Event
threshold

display oam critical-event

Syntax
display oam critical-event [ interface interface-type interface-number]
View
Any view
Default Level
2: System level
Parameters
interface interface-type interface-number: Specify a port by its type and number.
Description
Use the display oam critical-event command to display the statistics on critical Ethernet OAM link
events occurred on a port.
If you do not specify the interface keyword, this command displays the statistics on the critical
Ethernet OAM link events occurred on all the ports of the switch.
Examples
# Display the statistics on critical Ethernet OAM link events occurred on all the ports.
<Sysname> display oam critical-event
Port
: GigabitEthernet1/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault
:0
Table 5-4 display oam critical-event command output description
Field
Port
Link Status
Event statistic
Link Fault
Dying Gasp
Critical Event
Errored frame seconds event triggering threshold, which defaults
to 1.
Dying Gasp
: 0
Critical Event
Port index
Link status
Statistics on critical Ethernet OAM link events
Indicates whether a link fault is present: 0 for no and 1 for yes.
Indicate whether a fatal fault is present: 0 for no and 1 for yes.
Indicate whether a critical fault is present: 0 for no and 1 for yes.
Description
: 0
Description
5-6

Advertisement

Table of Contents
loading

Table of Contents