# Display configurations on each output destination.
<Sysname> display info-center
Information Center:enabled
Log host:
2.2.2.2, channel number : 8, channel name : channel8,
host facility local7
Console:
channel number : 0, channel name : console
Monitor:
channel number : 1, channel name : monitor
SNMP Agent:
channel number : 5, channel name : snmpagent
Log buffer:
enabled,max buffer size 1024, current buffer size 512,
current messages 512, dropped messages 0, overwritten messages 740
channel number : 4, channel name : logbuffer
Trap buffer:
enabled,max buffer size 1024, current buffer size 256,
current messages 216, dropped messages 0, overwritten messages 0
channel number : 3, channel name : trapbuffer
Information timestamp setting:
log - date, trap - date, debug - date,
loghost - date
Table 16-3 display info-center command output description
Information Center
Log host:
2.2.2.2, channel number : 8, channel
name : channel8,
host facility local7
Console:
channel number : 0, channel name :
console
Monitor:
channel number : 1, channel name :
monitor
SNMP Agent:
channel number : 5, channel name :
snmpagent
Field
16-3
Description
The current state of the information center,
which could be enabled or disabled.
Configurations on the log host destination (It can
be displayed only when the info-center loghost
command is configured), including IP address of
the log host, the channel number and channel
name used, and logging facility used.)
Configurations on the console destination,
including the channel number and channel
name used
Configurations on the monitor terminal
destination, including the channel number and
channel name used
Configurations on the SNMP module
destination, including the channel number and
channel name used