Oam Errored-Symbol Threshold - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

View
System view
Default Level
2: System level
Parameters
period-value: Errored symbol detection interval, ranging from 1 to 60 (in seconds).
Description
Use the oam errored-symbol period command to set the errored symbol detection interval.
Use the undo oam errored-symbol period command to restore the default.
By default, the errored symbol detection interval is one second.
Related commands: oam errored-symbol threshold, display oam link-event, display oam
configuration.
Examples
# Set the errored symbol detection interval to 10 seconds.
<Sysname> system-view
[Sysname] oam errored-symbol period 10

oam errored-symbol threshold

Syntax
oam errored-symbol threshold threshold-value
undo oam errored-symbol threshold
View
System view
Default Level
2: System level
Parameters
threshold-value: Errored symbol event triggering threshold, ranging from 0 to 4,294,967,295.
Description
Use the oam errored-symbol threshold command to set the errored symbol event triggering
threshold.
Use the undo oam errored-symbol threshold command to restore the default.
By default, the errored symbol event triggering threshold is 1.
Related commands: oam errored-symbol period, display oam link-event, display oam
configuration.