By default, you can use <Ctrl + C> to terminate a task. You can use the display
current-configuration command to verify the shortcut key you have defined.
Examples
# Define <Q> as the escape key.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface aux 0
[Sysname-ui-aux0] escape-key Q
To verify the configuration, do the following:
# Run the ping command to test the connection.
<Sysname> ping –c 20 125.241.23.46
PING 125.241.23.46: 56 data bytes, press Q to break
Request time out
--- 125.241.23.46 ping statistics ---
2 packet(s) transmitted
0 packet(s) received
100.00% packet loss
Enter <Q>, if the ping task is terminated and return to the current view, the configuration is correct.
<Sysname>

flow-control

Syntax
flow-control { hardware | none | software }
undo flow-control
View
AUX interface view
Default Level
2: System level
Parameters
hardware: Configures to perform hardware flow control.
none: Configures no flow control.
software: Configures to perform software flow control.
Description
Using flow-control command, you can configure the flow control mode on AUX port. Using undo
flow-control command, you can restore the default flow control mode.
By default, the value is none. That is, no flow control will be performed.