Oam Errored-Frame-Period Period - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

By default, the errored frame event triggering threshold is 1.
Related commands: oam errored-frame period, display oam link-event, display oam
configuration.
Examples
# Set the errored frame event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame threshold 100

oam errored-frame-period period

Syntax
oam errored-frame-period period period-value
undo oam errored-frame-period period
View
System view
Default Level
2: System level
Parameters
period-value: Errored frame period detection interval, ranging from 100 to 60000 (in milliseconds).
Description
Use the oam errored-frame-period period command to set the errored frame period detection
interval.
Use the undo oam errored-frame-period period command to restore the default.
By default, the errored frame period detection interval is 1000 milliseconds.
As for errored frame period event detection, the system first uses the following expression to convert
the errored frame period detection interval to the maximum number of 64-byte frames that can be
transmitted through an Ethernet port in the period:
where bandwidth is the port bandwidth (in bps) and "period" is the configured period (in milliseconds).
Related commands: oam errored-frame-period threshold, display oam link-event, display oam
configuration.
Examples
# Set the errored frame period detection interval to 10 seconds, that is, 10000 milliseconds.
<Sysname> system-view
[Sysname] oam errored-frame-period period 10000
bandwidth * period / (64 * 8 * 1000),