Display Cfd Md - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

If only MD is specified, this command will display the configurations of all MAs in that MD.
Examples
# Display the MA configuration information.
<Sysname> display cfd ma
3 maintenance domain(s) configured.
Maintenance domain: mdtest_5
1 maintenance association(s) belong(s) to maintenance domain mdtest_5:
Maintenance association: matest_5
Service instance: 5
Maintenance domain: mdtest_6
1 maintenance association(s) belong(s) to maintenance domain mdtest_6:
Maintenance association: matest_6
Service instance: 6
Maintenance association: matest_16
Service instance: 0
Maintenance domain: mdtest_7
1 maintenance association(s) belong(s) to maintenance domain mdtest_7:
Maintenance association: matest_7
Service instance: 7
Table 6-7 display cfd ma command output description
3 maintenance domain(s) configured.
Maintenance domain
1 maintenance association(s) belong(s) to
maintenance domain mdtest_5
Maintenance association
Service instance
VLAN
Level

display cfd md

Syntax
display cfd md
View
Any view
VLAN: 5
VLAN: 6
VLAN: 100
VLAN: 7
Field
6-15
Level: 5
Level: 6
Level: 6
Level: 7
Description
Number of MDs configured
Name of the MD
Number of MAs configured in the MD
Name of the MA
Service instance of the MA
VLAN to which the service instance belongs
Level of the MD to which the MA belongs