Garp Timer Leave - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default Level
2: System level
Parameters
timer-value: Join timer setting (in centiseconds), which must be a multiple of 5 in the range of two times
the Hold timer (inclusive) and half of the Leave timer (inclusive). When the Hold timer and the Leave
timer are set to their default, the value range for the Join timer is 20 (inclusive) to 25 (inclusive).
Description
Use the garp timer join command to set the GARP Join timer for an Ethernet port, Layer-2 aggregate
interface, or all ports in a port group.
Use the undo garp timer join command to restore the default of the GARP Join timer. This may fail if
the default is beyond the valid value range for the Join timer.
By default, the Join timer is set to 20 centiseconds.
Related commands: display garp timer, garp timer hold, garp timer leave.
Examples
# Set the GARP Join timer to 25 centiseconds, assuming that both the Hold timer and the Leave timer
are using the default.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] garp timer join 25

garp timer leave

Syntax
garp timer leave timer-value
undo garp timer leave
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default Level
2: System level
Parameters
timer-value: Leave timer setting (in centiseconds), which must be a multiple of 5 between two times the
Join timer (exclusive) and the LeaveAll timer setting (exclusive). When the Join timer and the LeaveAll
timer are set to their default, the value range for the Leave timer is 45 (inclusive) to 995 (inclusive).
Description
Use the garp timer leave command to set the GARP Leave timer for an Ethernet port, Layer-2