Ricoh M022 Service Manual page 663

Hide thumbs Also See for M022:
Table of Contents

Advertisement

No.
Type
High voltage power: Drum/ development bias output error
An error signal is detected for 0.2 seconds when charging the drum or development.
• High voltage leak
• Broken harness
491
D
• Defective drum unit or development unit
• Defective high voltage supply unit
1. Check or replace the harness.
2. Replace the drum unit or paper transfer unit.
3. Replace the high voltage supply unit.
No.
Type
High voltage power: Image transfer/ paper transfer bias output error
An error signal is detected for 0.2 seconds when charging the separation, image
transfer bet or paper transfer roller.
• High voltage leak
• Broken harness
492
C
• Defective image transfer belt unit or paper transfer unit
• Defective high voltage supply unit
1. Check or replace the harness.
2. Replace the image transfer belt unit or paper transfer unit.
3. Replace the high voltage supply unit.