Ricoh M022 Service Manual page 741

Hide thumbs Also See for M022:
Table of Contents

Advertisement

• 8941-002: Standby mode
• 8941-003: Panel off mode
• 8941-004: Low power mode
• 8941-005: Sleep mode
With this data, and the power consumption values from the specifications, we can estimate the amount of
energy that is used by the machine.
This should only be used as a reference value, because the power consumption specifications are measured
in a controlled environment with a constant power supply.
To get an exact measurement at the customers site, a watt meter must be used to measure the actual energy
consumed.
To use SP8941 to calculate the energy consumed:
• At the start of the measurement period, read the values of SP8941 001 to 005.
• At the end of the measurement period, read the values of SP8941 001 to 005 again.
• Find the amount of time spent in each mode (subtract the earlier measurement from the later
measurement).
• Multiply this by the power consumption spec for each mode.
• Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Machine
SP8941:
Condition
Machine
Status
Operating
001:
Operatin
g Time
Stand by
002:
Standby
(Ready)
Time
Energy save
003:
(Panel off)
Energy
Save Time
Low power
004: Low
Power
Time
CÓPIA NÃO CONTROLADA
Time at Start
Time at End
(min.)
(min.)
21089.0
21386.0
306163.0
308046.0
74000
75111.0
148000
150333
CÓPIA NÃO CONTROLADA
Running
Power
time
consumption
(hour)
Spec. (W)
( - )/
60 =
4.95
898
31.38
179
18.52
148.09
38.88
111
Energy Save
7
Power
consumption
(KWH)
( x )/1000
=
4.45
5.62
2.74
4.32
739

Advertisement