Pre-Idling Time
002
Specifies the fusing rotation time before executing SP1109-001.
Stop Time
003
Specifies the time for measuring the nip.
1112
[Environment Correction: Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature condition.
Temp.: Threshold: High
002
Specifies the threshold temperature for high temperature condition.
Low Temp. Correction
Specifies the temperature correction for the heating roller. When the low temperature
003
condition (specified with SP1112-001) is detected, the value of this SP is added to the heating
roller temperature.
High Temp. Correction
Specifies the temperature correction for the heating roller. When the high temperature
004
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
005 Offset Temp:Low
006 Offset Temp:High
1113
[Stand-by Mode Setting]
001
Wait Time AF Ready
Wait Time AF Recovery
003
Specifies the time for keeping the target temperature without any jobs after recovery
(SP1105-083).
Wait Time AF Job
004
Specifies the time for keeping the target temperature without any jobs after a last job.
CÓPIA NÃO CONTROLADA
*ENG
[0 to 120 / 0 / 1 sec/step]
* ENG
[5 to 30 / 20 / 1 sec/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
CÓPIA NÃO CONTROLADA
[10 to 23 / 17 / 1 deg/step]
[24 to 40 / 30 / 1 deg/step]
[0 to 15 / 5 / 1 deg/step]
[0 to 15 / 3 / 1 deg/step]
[0 to 15 / 5 / 0.1 deg/step]
[0 to 15 / 3 / 0.1 deg/step]
[0 to 60 / 30 / 1 sec/step]
[0 to 60 / 10 / 1 sec/step]
[0 to 60 / 10 / 1 sec/step]