Ricoh M022 Service Manual page 377

Hide thumbs Also See for M022:
Table of Contents

Advertisement

Panel Off Mode: Center
013
Specifies the heating roller temperature (center) in the panel off mode.
Panel Off Mode: Ends
014
Specifies the heating roller temperature (both ends) in the panel off mode.
Panel Off Mode: P-Roller
015
Specifies the presure roller temperature in the panel off mode.
016 Low Power: Center
017 Low Power: Ends
Low Power: P-Roller
018
Specifies the pressure roller temperature in the low power mode.
019 Off Mode: Center
020 Off Mode: Ends
Off Mode:P-Roller
021
Specifies the pressure roller temperature in the sleep mode.
030 to
The target fusing temperature for each paper type and mode can be adjusted by the following
239
SPs.
030 Plain1:FC:Simplex:Center
031 Plain1: FC: Simplex: Ends
032 Plain1:FC:Duplex:Center
033 Plain1: FC: Duplex: Ends
034 Plain1: BW: Simplex:Center
035 Plain1: BW: Simplex: Ends
036 Plain1: BW: Duplex:Center
037 Plain1: BW: Duplex: Ends
CÓPIA NÃO CONTROLADA
* ENG
* ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
CÓPIA NÃO CONTROLADA
[50 to 180 / 140 / 1 deg /step]
[50 to 180 / 140 / 1 deg /step]
[50 to 160 / 120 / 1 deg /step]
Specifies the heating roller temperature
(center or ends) in the low power mode.
[30 to 180 / 40 / 1 deg /step]
[30 to 160 / 110 / 1 deg /step]
Specifies the heating roller temperature
(center or ends) in the sleep mode.
[0 to 180 / 0 / 1 deg /step]
[0 to 170 / 0 / 1 deg /step]
[100 to 180 / 155 / 1 deg /step]
Main SP Tables-1
5
375

Advertisement

Table of Contents
loading

This manual is also suitable for:

M024M026M028

Table of Contents