004 Cancellation Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
001 Permissible Number
002 Detect Time
5416
[Access Information]
001 Access User Max Num
002 Access Password Max Num
CÓPIA NÃO CONTROLADA
Determines the length of time that the system waits
for correct input of the user ID and password after
a lockout has occurred. This setting is used only
*CTL
if SP5413-3 is set to "1" (on).
[1 to 9999 / 60 / 1 min.]
Switches on/off masking of continuously used
IDs and passwords that are identical.
[0 to 1 / 0 /1]
*CTL
0: Off
1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min.]
Sets the number of attempts to attack the system
with random passwords to gain illegal access to
*CTL
the system.
[0 to 100 / 30 / 1 attempt]
Sets the time limit to stop a password attack once
such an attack has been detected.
*CTL
[1 to 10 / 5 / 1 sec.]
Limits the number of users used by the access
exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 users]
Limits the number of passwords used by the
access exclusion and password attack detection
*CTL
functions.
[50 to 200 / 200 / 1 passwords]