Ricoh M022 Service Manual page 993

Hide thumbs Also See for M022:
Table of Contents

Advertisement

003 Cancellation On/Off
004 Cancellation Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
001 Permissible Number
002 Detect Time
5416
[Access Information]
CÓPIA NÃO CONTROLADA
Determines whether the system waits the
prescribed time for input of a correct user ID and
password after an account lockout has occurred.
[0 to 1 / 0 / 1]
*CTL
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct
user ID and password are entered.
Determines the length of time that the system waits
for correct input of the user ID and password after
a lockout has occurred. This setting is used only
*CTL
if SP5413-3 is set to "1" (on).
[1 to 9999 / 60 / 1 min.]
Switches on/off masking of continuously used
IDs and passwords that are identical.
[0 to 1 / 0 /1]
*CTL
0: Off
1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min.]
Sets the number of attempts to attack the system
with random passwords to gain illegal access to
*CTL
the system.
[0 to 100 / 30 / 1 attempt]
Sets the time limit to stop a password attack once
such an attack has been detected.
*CTL
[1 to 10 / 5 / 1 sec.]
CÓPIA NÃO CONTROLADA
System SP5-xxx
3
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

M024M026M028

Table of Contents