014 T Rank 2 Threshold
015 Correct Value Coef
3241
[Background Potential Setting]
001 Coefficient: Bk
002 Coefficient: C
003 Coefficient: M
004 Coefficient: Y
005 Offset: Bk
006 Offset: C
007 Offset: M
008 Offset: Y
[LD Power Setting]
3242
Adjusts the coefficient for LD power control value at the process control.
001 Standard Speed: Coefficient: Bk
002 Standard Speed: Coefficient: C
003 Standard Speed: Coefficient: M
004 Standard Speed: Coefficient: Y
005 Standard Speed: Offset: Bk
006 Standard Speed: Offset: C
007 Standard Speed: Offset: M
008 Standard Speed: Offset: Y
CÓPIA NÃO CONTROLADA
*ENG
[0 to 1 / 0.16 / 0.01 V/step]
*ENG
[1 to 2.5 / 9.99 / 0.01 /step]
*ENG
These are parameters for calculating the charge
bias referring to the development bias at process
*ENG
control.
[-1000 to 1000 / 0 / 1 /step]
*ENG
DC charge bias = Development bias x (1 + 0.001
*ENG
x these vales) + SP3-241-005 to -008
*ENG
These are additional values for calculating the
charge bias referring to the development bias at
*ENG
process control.
[0 to 255 / 158 / 1 V/step]
*ENG
DC charge bias = Development bias x (1 + 0.001
*ENG
x SP3-241-001 to -004) + these values
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
CÓPIA NÃO CONTROLADA
[-1000 to 1000 / 152 / 1 /step]
[-1000 to 1000 / 7 / 1 /step]
Main SP Tables-3