Ricoh M022 Service Manual page 795

Hide thumbs Also See for M022:
Table of Contents

Advertisement

001 Current Environmental:Display
002 Forced Setting
003 Absolute Humidity: Thresh 1
004 Absolute Humidity: Thresh 2
005 Absolute Humidity: Thresh 3
006 Absolute Humidity: Thresh 4
007 Current Temp.: Display
008 Relative Humidity: Display
Current Absolute Humidity:
009
Display
CÓPIA NÃO CONTROLADA
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
CÓPIA NÃO CONTROLADA
Displays the environmental condition, which
is measured in absolute humidity.
[1 to 5 / – / 1 /step]
3
1: LL (LL <= 4.3 g/m
)
2: ML (4.3 < ML <= 11.3 g/m
3: MM (11.3 < MM <= 18.0 g/m
4: MH (18.0 < MH <= 24.0 g/m
3
5: HH (24.0 g/m
< HH)
Selects the environmental condition
manually. DFU
[0 to 5 / 0 / 1 /step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Changes the humidity threshold between LL
and ML. DFU
[0 to 100 / 4.3 / 0.01 g/m
Changes the humidity threshold between ML
and MM. DFU
[0 to 100 / 11.3 / 0.01 g/m
Changes the humidity threshold between
MM and MH. DFU
[0 to 100 / 18.0 / 0.01 g/m
Changes the humidity threshold between
MH and HH. DFU
[0 to 100 / 24.0 / 0.01 g/m
Displays the current temperature.
[0 to 100 / 0 / 1 deg/step]
Displays the current relative humidity.
[0 to 100 / 0 / 1%RH/step]
Displays the absolute humidity.
[0 to 100 / 0 / 0.01 g/m
System SP2-xxx
3
)
3
)
3
)
3
3
/step]
3
/step]
3
/step]
3
/step]
3
/step]
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

M024M026M028

Table of Contents