Page: Interrupt: FC
005
Adjusts the threshold of the line position adjustment for color printing mode during jobs.
Page: Standby: BW
Adjusts the threshold of the line position adjustment for BW printing mode in stand-by mode.
006
The line position adjustment is done when the number of outputs in BW printing mode reaches
the value specified with this SP and the condition of SP2-193-008 or SP2-193-009 is
satisfied.
Page: Standby: FC
Adjusts the threshold of the line position adjustment for BW printing mode in stand-by mode.
007
The line position adjustment is done when the number of outputs in color printing mode
reaches the value specified with this SP and the condition of SP2-193-008 or SP2-193-009
is satisfied.
Temp
Adjust the temperature change threshold for the line position adjustment (Mode b: adjustment
008
once). The timing for line position adjustment depends on the combinations of several
conditions.
Time
009
Adjust the time threshold for the line position adjustment (Mode b: adjustment once). The
timing for line position adjustment depends on the combinations of several conditions.
Magnification
010
Adjusts the magnification threshold for line position adjustment. If the length of the main scan
is changed by this amount since the previous MUSIC, then MUSIC is done again.
Temp 2
Adjust the temperature change threshold for the line position adjustment (Mode a: adjustment
011
twice). The timing for line position adjustment depends on the combinations of several
conditions.
Time 2
012
Adjust the time threshold for the line position adjustment (Mode a: adjustment twice). The
timing for line position adjustment depends on the combinations of several conditions.
013 Time 3
CÓPIA NÃO CONTROLADA
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
CÓPIA NÃO CONTROLADA
[0 to 999 / 200 / 1 page/step]
[0 to 999 / 100 / 1 page/step]
[0 to 999 / 100 / 1 page/step]
[0 to 100 / 5 / 1 deg/step]
[1 to 1440 / 300 / 1 minute/step]
[0 to 10 / 1 / 0.1 %/step]
[0 to 100 / 10 / 1 deg/step]
[1 to 9999 / 600 / 1 minute/step]
[1 to 1440 / 300 / 1 minute/step]
System SP2-xxx