2198
[Music A/D Interval] DFU
001 ADC Trigger
2199
[Music Error Time Setting] DFU
001 Error Detection Counter
[Skew Origin Set]
2220
Resets the value of the skew adjustment motor for each color.
These SPs must be executed when a new laser optics housing unit is installed.
001 C:Skew Motor
002 M:Skew Motor
003 Y:Skew Motor
[Dev. DC Bias:Fixed] DFU
Development DC Bias Adjustment
Adjusts the development bias.
2229
Development bias is automatically adjusted during process control; therefore, adjusting these
settings has no effect while Process Control (SP3-041-001 Default: ON) is activated.
After deactivating Process Control with SP3-041-001, the values in these SP modes are used
for printing.
001 Bk
002 C
003 M
004 Y
[Temperature/Humidity:Display]
2241
Displays the environment temperature and humidity.
001 Temperature
002 Relative Humidity
CÓPIA NÃO CONTROLADA
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
-
[–1280 to 1270 / 0 / 0.1 deg/step]
-
[0 to 1000 / 0 / 0.1 %RH/step]
CÓPIA NÃO CONTROLADA
[7.5 to 20 / 10 / 0.1 s/step]
[0.1 to 9.9 / 3 / 0.1 sec /step]
-
[0 to 800 / 450 / 1 –V/step]
System SP2-xxx