No.
Type
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
CTL
651
An unexpected error occurs when the modem (Embedded RCG-M) tries to call the
C
center with a dial up connection.
• Caused by a software bug
No action required because this SC does not interfere with operation of the machine.
No.
Type
Remote service ID2 mismatch error
The ID2 in the individual certificate does not match the ID2 in the NVRAM on the
controller board.
• The controller board in this machine has already been used in a machine in
which RC Gate was installed.
• The controller board NVRAM in this machine has already been used in a
machine in which RC Gate was installed.
If an error occurs at installation of the RC Gate:
652
CTL
1. Check that the individual certificate is correct for the NVRAM in the machine
and that the ID2 is correct.
2. Reinstall the RC Gate after writing the common certificate.
If an error occurs after installation of the RC Gate:
1. Clear the RC Gate data.
2. Check that the individual certificate is correct for the NVRAM in the machine
and that the ID2 is correct.
3. Reinstall the RC Gate after writing the common certificate.