Ricoh M022 Service Manual page 917

Hide thumbs Also See for M022:
Table of Contents

Advertisement

Display: latest YMCK
001
Displays the developer initialization result. See the "Error Condition Tables" in the Process
Control Error section for details on the meaning of each code.
All colors are displayed. Values are displayed in the order Y M C Bk.
e.g., 1 (Y) 1 (M) 2 (C) 1 (Bk): Initialization of Cyan failed but the others succeeded.
3015
[Forced Toner Supply: Execute] Forced Toner Supply ([Color])
001 Execution: ALL
002 Execution: COL
003 Execution: Bk
004 Execution: C
005 Execution: M
006 Execution: Y
[Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color])
3016
Specifies the manual toner supply time for each color.
001 Supply Time: Bk
002 Supply Time: C
003 Supply Time: M
004 Supply Time: Y
[Vt Limit Error]
3020
DFU
001 Delta Vt Threshold
002 Upper Threshold
003 Thresh Num of Upper Counter
CÓPIA NÃO CONTROLADA
*ENG
-
-
[0 or 1 / 0 / 1 /step]
-
Executes the manual toner supply to the
-
development unit.
-
-
*ENG
*ENG
[0 to 30 / 4 / 1 sec/step]
*ENG
*ENG
*ENG
[0 to 5 / 5 / 0.01 V/step]
*ENG
[0 to 5 / 4.7 / 0.01 V/step]
*ENG
[0 to 99 / 20 / 1 time/step]
CÓPIA NÃO CONTROLADA
[0 to 9999 / - / 1 /step ]
1: Success
2 to 9: Failure