3. Appendix: SP Mode Tables
092 CERT: Issuer
093 CERT: Valid Start
094 CERT: Valid End
3
Selection Country
Select the country where embedded RCG-M is installed in the machine. After selecting the
country, you must also set the following SP codes for embedded RCG-M:
• SP5816-153
150
• SP5816-154
• SP5816-161
0: Japan, 1: USA, 2: Canada, 3: UK, 4: Germany, 5: France, 6: Italy,
7: Netherlands, 8: Belgium, 9: Luxembourg, 10: Spain
Line Type Authentication Judgment
Press [Execute].
Setting this SP classifies the telephone line where embedded RCG-M is connected as either
dial-up (pulse dial) or push (DTMF tone) type, so embedded RCG-M can automatically
151
distinguish the number that connects to the outside line.
• The current progress, success, or failure of this execution can be displayed with
• If the execution succeeded, SP5816-153 will display the result for confirmation and
264
CÓPIA NÃO CONTROLADA
SP5816-152.
SP5816-154 will display the telephone number for the connection to the outside line.
CÓPIA NÃO CONTROLADA
Displays the common name of the issuer of the @Remote
certification. CN = the following 30 bytes. Asteriskes
(****) indicate that no DESS exists.
Displays the start time of the period for which the current
@Remote certification is enabled.
Displays the end time of the period for which the current
@Remote certification is enabled.