3. Appendix: SP Mode Tables
Sets the alarm to sound for the specified jam level (document misfeeds are not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
001
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
3
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
5505
counter decreases by "1" when an SC is not detected during a set number of copied sheets
(for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
[Supply Alarm]
5507
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm
002 Staple Supply Alarm
003 Toner Supply Alarm
Waste Toner Bottle Supply
006
Alarm
080 Toner Call Timing
252
CÓPIA NÃO CONTROLADA
*CTL
*CTL
-
0: Off, 1: On
0: Off, 1: On
0: Off, 1: On
0: Off, 1: On
Changes the timing of the "Toner Supply Call" via the
@Remote, when the following conditions occur.
0: At replacement
1: At near end
CÓPIA NÃO CONTROLADA
[0 to 255 / 32 / 100 copies /step]