Ricoh M022 Service Manual page 965

Hide thumbs Also See for M022:
Table of Contents

Advertisement

001 Lamp: OFF
002 Lamp: ON
[Scan]
4014
Execute the scanner free fun with each mode.
001 HP Detection Enable
002 HP Detection Disable
4020
[DF Dust Check]
001 Dust Detect: ON/OFF
002 Dust Detect: Level
003 Dust Reject: Level
[Org Edge Mask]
4400
Set the Mask for Original.
These SPs set the area to be masked during platen (book) mode scanning.
CÓPIA NÃO CONTROLADA
*ENG
OFF or ON
-
Scanner free run with HP sensor check.
-
Scanner free run without HP sensor check.
Turns the ADF scan glass dust check on/ off.
*ENG
[0 or 1 / 0 / 1 /step]
0: OFF, 1: ON
Selects the detect level.
[0 to 8 / 4 / 1 /step]
*ENG
0: lowest detection level
8: highest detection level
Selects the level of the sub scan line correction
when using the ARDF.
[0 to 4 / 0 / 1 /step]
0: Off
*ENG
1: Weakest
2: Weak
3: Strong
4: Strongest
*ENG
CÓPIA NÃO CONTROLADA
System SP4-xxx
3
219

Advertisement

Table of Contents
loading

This manual is also suitable for:

M024M026M028