Ricoh M022 Service Manual page 376

Hide thumbs Also See for M022:
Table of Contents

Advertisement

5. System Maintenance
009 P.Feed Temp:MThick:P-Roll:FC
010 Upper Limit Temp
011 Offset: Feed Start
012 Offset: Feed Start: M-Thick
013 Offset: Feed Start: 600: Plain1: BW
014 Offset: Feed Start: 600: Plain2: BW
030 Offset: Feed Start: Time
031 Offset:Feed Start:1200
033 Offset: Feed Start: Glossy
5
1105
[Fusing Temperature] Fusing Temperature Adjustment
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, P-Roller –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
Fusing Ready Temp
001
Specifies the heating roller target temperature for the ready condition.
002 Fusing Ready: Offset
003 P-Roll Ready Target Temp.
P-Roll Ready Temp
Sets the heating roller offset temperature at the end of the heating roller. This value is one of
007
the thresholds to determine if the machine is at the heating roller target temperature during
warm-up.
010 Stand-By: Center
011 Stand-By: Ends
Stand-By:P-Roller
012
Sets the pressure roller offset temperature. This value is one of the thresholds to determine if
the machine is at the heating roller target temperature during warm-up.
374
CÓPIA NÃO CONTROLADA
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
* ENG
* ENG
* ENG
CÓPIA NÃO CONTROLADA
[0 to 160 / 100/ 1 deg/step]
[0 to 100 / 25/ 1 deg/step]
[0 to 100 / 20/ 1 deg/step]
[0 to 100 / 10/ 1 deg/step]
[0 to 100 / 25/ 1 deg/step]
[0 to 100 / 25/ 1 deg/step]
[15 to 500 / 60 / 1 sec/step]
[0 to 100 / 15 / 1 deg/step]
[0 to 100 / 15/ 1 deg/step]
[100 to 180 / 160 / 1 deg/step]
[5 to 30 / 11 / 1 deg/step]
[50 to 160 / 120 / 1 deg/step]
[0 to 150 / 20 / 1 deg/step]
[50 to 180 / 160 / 1 deg/step]
[50 to 180 / 160 / 1 deg/step]
[50 to 160 / 140 / 1 deg/step]