2 Parameters
2.2 List of parameters
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD telegr ext
B_INF
Can be changed: T
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
370
Description:
Sets the send and receive telegram.
Contrary to p0922, a telegram can be selected using p2079 and subsequently expanded.
Value:
370:
371:
999:
Dependency:
Refer to: p0922
Note:
For p0922 < 999 the following applies:
p2079 has the same value and is inhibited. All of the interconnections and extensions contained in the telegram are
inhibited.
For p0922 = 999 the following applies:
p2079 can be freely set. If p2079 is also set to 999, then all of the interconnections can be set.
For p0922 = 999 and p2079 < 999 the following applies:
The interconnections contained in the telegram are inhibited. However, the telegram can be extended.
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD telegr ext
CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
390
Description:
Sets the send and receive telegram.
Contrary to p0922, a telegram can be selected using p2079 and subsequently expanded.
Value:
390:
391:
392:
393:
394:
395:
396:
999:
Note:
For p0922 < 999 the following applies:
p2079 has the same value and is inhibited. All of the interconnections and extensions contained in the telegram are
inhibited.
For p0922 = 999 the following applies:
p2079 can be freely set. If p2079 is also set to 999, then all of the interconnections can be set.
For p0922 = 999 and p2079 < 999 the following applies:
The interconnections contained in the telegram are inhibited. However, the telegram can be extended.
p2079
IF1 PROFIdrive PZD telegram selection extended / IF1 PZD telegr ext
ENC
Can be changed: T
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
81
Description:
Sets the send and receive telegram.
492
SIEMENS telegram 370, PZD-1/1
SIEMENS telegram 371, PZD-5/8
Free telegram configuration with BICO
SIEMENS telegram 390, PZD-2/2
SIEMENS telegram 391, PZD-3/7
SIEMENS telegram 392, PZD-3/15
SIEMENS telegram 393, PZD-4/21
SIEMENS telegram 394, PZD-3/3
SIEMENS telegram 395, PZD-4/25
SIEMENS telegram 396, PZD-20/21
Free telegram configuration with BICO
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
999
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
999
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
999
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
999
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
999