Cu Digital Inputs Simulation Mode Setpoint / Cu Di Simul Setp - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
20
21
Dependency:
The setpoint for the input signals is specified using p0796.
Refer to: p0796, p9620
Notice:
If a digital input is used as signal source for the function "STO" (BI: p9620) then it is not permissible to select the
simulation mode and this is rejected.
To the terminal designation:
The first designation stands for CU320, the second for CU310.
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
p0796

CU digital inputs simulation mode setpoint / CU DI simul setp

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
CU_G150_PN
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the setpoint for the input signals in the digital input simulation mode.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
DI 0 (X122.1/X121.1)
DI 1 (X122.2/X121.2)
DI 2 (X122.3/X121.3)
DI 3 (X122.4/X121.4)
DI 4 (X132.1 / -)
DI 5 (X132.2 / -)
DI 6 (X132.3 / -)
DI 7 (X132.4 / -)
DI/DO 8 (X122.9/X121.7)
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 12 (X132.9/X131.1)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI 16 (X122.5/X120.3)
DI 17 (X122.6/X120.4)
DI 20 (X132.5/X120.9)
DI 21 (X132.6/X120.10)
Signal name
DI 0 (X122.1/X121.1)
DI 1 (X122.2/X121.2)
DI 2 (X122.3/X121.3)
DI 3 (X122.4/X121.4)
DI 4 (X132.1 / -)
DI 5 (X132.2 / -)
DI 6 (X132.3 / -)
DI 7 (X132.4 / -)
DI/DO 8 (X122.9/X121.7)
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 12 (X132.9/X131.1)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI 16 (X122.5/X120.3)
DI 17 (X122.6/X120.4)
1 signal
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
2 Parameters
2.2 List of parameters
0 signal
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Access level: 2
Func. diagram: 2020, 2030,
2031, 2100, 2119, 2120, 2130,
2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
247