2 Parameters
2.2 List of parameters
r1239.0...13

CO/BO: Armature short-circuit / DC braking status word / ASC/DCBRK ZSW

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the status word for armature short-circuit.
Bit field:
Bit
00
01
02
03
04
05
06
08
09
10
11
12
13
Dependency:
Refer to: p1230, p1231, p1232, p1233, p1234, p1235, p1236, p1237
Note:
External armature short-circuit (bits 0 ... 3):
Re bit 00:
Using this signal, the motor is short-circuited through an external contactor circuit. This means that this BO: p1239.0
must be interconnected e.g. to a digital output.
Re bit 01:
This signal indicates the state of the contactor to establish the armature short-circuit. To do this, BI: p1235 must be
interconnected to a digital input.
Re bit 02:
The external armature short-circuit configuration is ready and is activated as soon as the activation criterion is
fulfilled.
Re bit 03:
1: A feedback signal from an external contactor was parameterized in BI: p1235.
Internal voltage protection / internal armature short-circuit (bits 4 ... 6):
Re bit 04:
a) Internal voltage protection (p1231 = 3) was selected and the Motor Module does not support the autonomous
internal voltage protection (r0192.10 = 0).
The Control Unit issues the command to the Motor Module to short-circuit the motor through the power
semiconductors.
a) Internal voltage protection (p1231 = 3) was selected and the Motor Module supports the autonomous internal
voltage protection (r0192.10 = 1).
The Motor Module decides autonomously whether the armature short-circuit is activated. In this case, the following
applies: r1239.4 = r1239.5.
c) Internal armature short-circuit (p1231 = 4) was selected.
The Control Unit issues the command to the Motor Module to short-circuit the motor through the power
semiconductors.
Re bit 05:
The Motor Module signals that the motor is short-circuited in the Motor Module through the power semiconductors.
332
Signal name
External armature short-circuit
External armature short-circuit contactor
feedback signal
External armature short-circuit ready
External armature short-circuit with
contactor feedback signal
Internal armature short-circuit
Internal armature short circuit feedback
signal from power unit
Internal armature short-circuit ready
DC braking active
DC current injection active
DC braking ready
Armature short circuit/DC braking selected
DC braking selection internally inhibited
DC braking for OFF1/OFF3
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Active
Closed
Yes
Yes
Active
Active
Yes
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH2), 04/2014, A5E03263479A
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Inactive
Open
No
No
Inactive
Inactive
No
No
No
No
No
No
No
SINAMICS G130/G150