Co: Excitation Current Setpoint / I_Exc_Setp; Co: Current Model Load Angle / I_Mod Load Angle; Current Model Controller Dynamic Factor / I_Mod_Ctr Dyn_Fact; Current Model Controller P Gain / I_Mod_Ctrl Kp - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1626

CO: Excitation current setpoint / I_exc_setp

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [%]
Description:
Displays the calculated excitation current setpoint.
Dependency:
Refer to: p0390
r1627

CO: Current model load angle / I_mod load angle

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [°]
Description:
Displays the load angle of the current model.
p1628[0...n]

Current model controller dynamic factor / I_mod_ctr dyn_fact

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: ASM, PEM, REL
Min
1 [%]
Description:
Sets the dynamic response factor for the current model controller.
p1629[0...n]

Current model controller P gain / I_mod_ctrl Kp

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
0.000
Description:
Sets the proportional gain for the current model controller.
This value is automatically pre-set using p3900 or p0340 when commissioning has been completed.
p1630[0...n]
Current model controller integral time / I_mod_ctrl Tn
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
0.00 [ms]
Description:
Sets the integral time for the current model controller.
This value is automatically pre-set using p3900 or p0340 when commissioning has been completed.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2005
Max
- [°]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
400 [%]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
100000.000
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
10000.00 [ms]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
- [°]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
50 [%]
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0.000
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]