2 Parameters
2.2 List of parameters
r3671[0...n]

CO: VSM 10 V input CT 1 actual value / VSM CT 1 I_act

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [A]
Description:
Displays the current actual value from current transducer (CT) 1 at the 10 V input of the Voltage Sensing Module
(VSM).
Dependency:
Refer to: p3670
Note:
The CT for phase 1 is connected at terminals X520.1 and X520.2 of the VSM.
r3672[0...n]

CO: VSM 10 V input CT 2 actual value / VSM CT 2 I_act

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [A]
Description:
Displays the current actual value from current transducer (CT) 2 at the 10 V input of the Voltage Sensing Module
(VSM).
Dependency:
Refer to: p3670
Note:
The CT for phase 2 is connected at terminals X520.3 and X520.4 of the VSM.
r3673[0...n]

CO: VSM 10 V input 1 actual value / VSM inp 1 U_act

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [V]
Description:
Displays the actual value of the voltage measured at the 10 V input 1 of the Voltage Sensing Modules (VSM).
Dependency:
Refer to: p3670
Note:
10 V input 1: Terminals X520.1 and X520.2
r3674[0...n]

CO: VSM 10 V input 2 actual value / VSM inp 2 U_act

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [V]
Description:
Displays the actual value of the voltage measured at the 10 V input 2 of the Voltage Sensing Modules (VSM).
Dependency:
Refer to: p3670
Note:
10 V input 2: Terminals X520.3 and X520.4
574
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: p2001
Max
- [V]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
- [V]