r0774[0...2]

Test sockets output voltage / TestSkts U_output

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
- [V]
Description:
Displays the actual output voltage for the test sockets.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
p0776[0...2]

Test socket mode / Test skt mode

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
96
Description:
Sets the mode for the test sockets.
Value:
96:
97:
98:
99:
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784, r0786, p0788, p0789, r0790
p0777[0...2]

Test socket characteristic value x1 / Test skt char x1

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
-100000.00 [%]
Description:
The scaling characteristic for the test sockets is defined using two points.
This parameter specifies the x coordinate (percentage) of the first point on the characteristic.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Can only be set when p0776 = 99.
Refer to: p0778, p0779, p0780, r0786
Note:
The value 0.00 % corresponds to 2.49 V.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Physical address (32-bit integer signal unsigned)
Physical address (32-bit integer signal)
Physical address (32-bit floating-point signal)
BICO signal
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
100000.00 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 4
Func. diagram: 8134
Unit selection: -
Expert list: 1
Factory setting
99
Access level: 2
Func. diagram: 8134
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]