r3889.0...10

CO/BO: ESM status word / ESM ZSW

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Display and BICO output for the status word of the essential service mode (ESM).
Bit field:
Bit
00
01
02
07
08
09
10
Note:
ESM: Essential Service Mode
p3900

Completion of quick commissioning / Compl quick_comm

B_INF
Can be changed: C2(1)
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Exits the quick commissioning (p0010 = 1) with automatic calculation of all of the parameters that depend on the
entries made during the quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning. The interconnections of
PROFIBUS PZD telegram selection (p0922) and the interconnections via p0700 are re-established and all of the
dependent filter and closed-loop control parameters are calculated (corresponding to p0340 = 1).
p3900 = 2 includes the restoration of the interconnections of PROFIBUS PZD telegram selection (p0922) and the
interconnections via p0700 and the calculations corresponding to p0340 = 1.
p3900 = 3 only includes the end of quick commissioning.
Value:
0:
1:
2:
3:
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
When the calculations have been completed, p3900 and p0010 are automatically reset to a value of zero.
p3900
Completion of quick commissioning / Compl quick_comm
VECTOR_G
Can be changed: C2(1)
Data type: Integer16
P-Group: Displays, signals
Not for motor type: -
Min
0
Description:
Exits quick commissioning (p0010 = 1) with automatic calculation of all parameters of all existing drive data sets that
depend on the entries made during quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Essential service mode (ESM) activated
Direction of rotation inverted
Setpoint signal lost
Setpoint TB30/TM31 analog input
parameterized (p3886)
Power unit not permissible (permissible
p0201 >= 14000)
Response OFF1/OFF2 activated
Automatic restart interrupted (F07320)
No quick parameterization
Quick parameterization after parameter reset
Quick param. (only) for controller par. and reset for BICO par
Completion of quick commissioning
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 7033
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
-
-
-
-
593