Si Motion Sbt Brake Holding Torque / Sbt Brake M_Stop; Si Motion Sbt Test Torque Factor Sequence 1 / Sbt M_Test Fact 1; Si Motion Sbt Test Duration Sequence 1 / Sbt T_Test Seq 1 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p10209[0...1]

SI Motion SBT brake holding torque / SBT brake M_stop

VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
1.00 [Nm]
Description:
Sets the effective holding torque on the motor side of the brake to be tested.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
The holding torque of an external brake should be converted to the motor side.
Conversion factor:
- motor type = rotary and axis type = linear: p9522 / (p9521 x p9520)
- otherwise: p9522 / p9521
Further, the efficiency of the mechanical system should be taken into account.
Refer to: p10210, p10220
Note:
The test torque effective for the brake test can be set for each sequence using a factor (p10210, p10220).
p10210[0...1]

SI Motion SBT test torque factor sequence 1 / SBT M_test fact 1

VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.30
Description:
Sets the factor for the test torque of sequence 1 for the safe brake test.
The factor is referred to the holding torque of the brake (p10209).
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10209, p10230, p10235
Note:
The test sequence is selected using p10230[4] or p10235.4.
p10211[0...1]

SI Motion SBT test duration sequence 1 / SBT t_test seq 1

VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
20 [ms]
Description:
Sets the test duration for sequence 1 for the safe brake test.
The test torque is available for this time at the closed brake.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
Refer to: p10230, p10235
Note:
The test sequence is selected using p10230[4] or p10235.4.
The set time is rounded internally to an integer multiple of the monitoring clock (p9500/p9300) cycle.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
60000.00 [Nm]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1.00
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
10000 [ms]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
10.00 [Nm]
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
1.00
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
1000 [ms]