2 Parameters
2.2 List of parameters
p0833

Data set changeover configuration / DS_chng config

VECTOR_G
Can be changed: C2(15)
Data type: Unsigned16
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the configuration for the motor and encoder changeover.
Bit field:
Bit
00
01
02
Note:
Re bit 00:
When the bit is set and the motor has to be changed over, then p0827 must be set differently in the appropriate motor
data sets.
Re bit 02:
The bit defines whether, for an EDS changeover, the status signal Gn_ZSW.14 is suppressed (parking encoder
active).
Re motor changeover to running motor:
The "flying restart" function should also be activated (p1200) when changing over to a motor that is already running.
r0835.2

CO/BO: Data set changeover status word / DDS_ZSW

ENC
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word for the drive data set changeover.
Bit field:
Bit
02
Note:
Re bit 02:
A data set changeover is delayed by the time required for the internal parameter calculation.
r0835.0...11
CO/BO: Data set changeover status word / DDS_ZSW
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word for the drive data set changeover.
Bit field:
Bit
00
01
02
04
05
06
07
08
10
11
254
Signal name
Contactor changeover from the
application/drive
Pulse suppression by application/drive
Suppress drive parking for EDS changeover Yes
Signal name
Internal parameter calculation active
Signal name
Motor changeover active
Encoder changeover active
Internal parameter calculation active
Armature short circuit active
Identification running
Friction characteristic record running
Rotating measurement running
Motor data identification running
Wait for pulse suppression
Wait for motor changeover feedback signal
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
application
application
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0010 bin
0 signal
Drive
Drive
No
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
SINAMICS G130/G150
FP
-
-
-
FP
-
FP
8575
-
-
-
-
-
-
-
-
-